3D Volumetric Lung Nodule Analysis

Figure 1

Figure 2

Figure 3

History:  60 year old male smoker. 4 mm right upper lobe pulmonary nodule on CT. The patient was referred to Main Street Radiology for 6-month follow-up CT.


 

Findings: Non-contrast Chest CT was performed on a 16-detector spiral CT. A small right upper lobe nodule is seen on the routine 5mm image (figure 1), which is better appreciated on the high-resolution 0.75 mm image (figure 2). 3D volumetric rendering of the nodule was also performed (figure 3). The nodule measured 36 mm3 in volume, corresponding to 4.1 mm average diameter. This is unchanged since the prior exam, compatible with a benign process.


Discussion:  Solitary pulmonary nodule (SPN) is a common finding in clinical practice. These lesions whether found on conventional X-ray or CT scan are usually benign, but a neoplastic process must be excluded, especially in patients with risk factors for bronchogenic carcinoma. Guidelines for evaluating SPNs are not clearly outlined, and opinions vary greatly (AJR 2001; 176:1363-1369).

When a nodule is seen on X-ray, CT scan of the chest should be performed, to exclude an artifact and to better characterize the lesion. Lung nodules may appear calcified on conventional X-ray, suggesting a benign diagnosis, which may eliminate the need for a CT. However, it has been shown that determination of presence of calcification in nodules on plain films is not reliable (AJR 2001; 176:201-204).

When performing a CT for pulmonary nodules, high-resolution images should be performed, with slice thickness of 1 mm or less, which will enable the Radiologist to determine if the lesion is benign. If the lesion is non-specific in appearance, 3D volumetric analysis produces more accurate measurement of the lesion if follow-up studies are warranted. In a recently published study (Radiology 2004; 231: 453-458), routine 2-dimensional measurements were shown to be inaccurate for small nodules, with large inter-observer and intra-observer variability. In a different study, 3D volumetric measurement of nodule size has been shown to be significantly more accurate and reproducible (Radiology 2004; 231:446-452).

Considering the reproducibility of volumetric measurement and growth rate of bronchogenic carcinoma, mathematical analysis was performed to determine the appropriate time interval for follow-up of pulmonary nodules (Radiology 2004; 231:446-452). 1-month follow-up was sufficient to detect change in 10 mm nodules, while 12 month follow-up was necessary for nodules less than 3 mm. Using 2-dimensional measurements only, 12-month follow-up was necessary for nodules less than 5 mm (Radiology 2004; 231:164-168).

Positron Emmision Tomography (PET) has shown to be highly accurate for assessment of pulmonary nodules (JAMA 2001; 285:914-24), with sensitivity reported at 97%. PET scan should be considered for all SPN greater that 8 mm.

Combining the volumetric spiral-CT and PET data, the following table summarizes the general guidelines for follow-up of SPN based on size:

<3 mm 12 month follow up CT
3-5 mm   6  month follow up CT
5-8  mm   3  month follow up CT
> 8mm PET

At Main Street Radiology, we utilize a 3D-volumetric nodule-analysis software with our 16-detector spiral CT, and we are the first facility in Queens to perform PET scans. With these new technologies, we are best equipped to optimally evaluate pulmonary nodules, significantly reducing the number of negative biopsies and thoracotomies, while minimizing delay in diagnosis.

 


32-25 Francis Lewis Blvd.
Bayside, New York 11358


44-01 Francis Lewis Blvd.
Bayside, New York 11358

                                                                     136-25  37th Ave
Flushing, NY 11354

Tel: 718-428-1500
Fax: 718-428-2475

 


PET ScanCT Scan  |  MRI Interventional Radiology 

Home
  |  About Our Practice  |  About Our Physicians  |  Monthly Newsletter 
Modalities / Services  |  Maps & Directions  |  Contact Us  |  Terms of Use 
Notice of Privacy Practices

Copyright © 2002-2004 Main Street Radiology and MedNet Technologies, Inc.
 All Rights Reserved. This site is optimized for a display setting of 800 by 600 pixels, or greater.

MedNet-Sites by MedNet Technologies

MedNet-Sites™ - Powered by MedNet Technologies, Inc.